Back to articles
General Papers
Volume: 47 | Article ID: art00004
Image
A New Technique for Measuring the Distribution of Charge-to-Mass Ratio for Toner Particles with On-Line Use
  DOI :  10.2352/J.ImagingSci.Technol.2003.47.3.art00004  Published OnlineMay 2003
Abstract

In this paper, we present a technique for measuring the value of charge-to-mass ratio in toners using a newly developed apparatus in which charged toner particles are transported above a periodic array of conductors driven by four-phase rectangular pulses. At the end of the flow path of toner particles in the transport system, parallel electrodes are set up for sensing charge-to-mass ratio. The sensed input signal is amplified by differential amplifier and is converted to digital values. By analyzing the sensed signal, the value of the ratio for the charged toner particles can be calculated. This technique can measure easily the mean value and its distribution under coditions of on-line use. We find that the distribution shows a good correspondence with the result of the E-Spart method near the peak range.

Subject Areas :
Views 23
Downloads 0
 articleview.views 23
 articleview.downloads 0
  Cite this article 

Keiji Taniguchi, Hiroaki Yamamoto, Yutaka Nakano, Takanori Sakai, Syuichi Morikuni, Sadakazu Watanabe, Yoichi Yamamoto, "A New Technique for Measuring the Distribution of Charge-to-Mass Ratio for Toner Particles with On-Line Usein Journal of Imaging Science and Technology,  2003,  pp 224 - 228,  https://doi.org/10.2352/J.ImagingSci.Technol.2003.47.3.art00004

 Copy citation
  Copyright statement 
Copyright © Society for Imaging Science and Technology 2003
  Login or subscribe to view the content