<?xml version="1.0"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.1 20050630//EN" "http://uploads.ingentaconnect.com/docs/dtd/ingenta-journalpublishing.dtd">
<article article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="aggregator">72010351</journal-id>
      <journal-title>Conference on Colour in Graphics, Imaging, and Vision</journal-title>
      <abbrev-journal-title>conf colour graph imag vis</abbrev-journal-title>
      <issn pub-type="ppub">2158-6330</issn><issn pub-type="epub"/>
      <publisher>
        <publisher-name>Society of Imaging Science and Technology</publisher-name>
        <publisher-loc>7003 Kilworth Lane, Springfield, VA 22151, USA</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta><article-id pub-id-type="doi">10.2352/CGIV.2008.4.1.art00130</article-id>
      <article-id pub-id-type="sici">2158-6330(20080101)2008:1L.608;1-</article-id>
      <article-id pub-id-type="publisher-id">cgiv_v2008n1/splitsection130.xml</article-id>
      <article-id pub-id-type="other">/ist/cgiv/2008/00002008/00000001/art00130</article-id>
      <article-categories>
        <subj-group>
          <subject>Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Multispectral Imaging with Flash Light Sources</article-title>
      </title-group>
      <contrib-group>
        <contrib>
          <name>
            <surname>Brauers</surname>
            <given-names>Johannes</given-names>
          </name>
        </contrib>
        <contrib>
          <name>
            <surname>Helling</surname>
            <given-names>Stephan</given-names>
          </name>
        </contrib>
        <contrib>
          <name>
            <surname>Aach</surname>
            <given-names>Til</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date>
        <day>01</day>
        <month>01</month>
        <year>2008</year>
      </pub-date>
      <volume>2008</volume>
      <issue>1</issue>
      <fpage>608</fpage>
      <lpage>612</lpage>
      <permissions>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract>
        <p>Flash photography is widely used in professional studios due to its high intensities and the resulting short exposure times. However, most multispectral image acquisition systems use continuous light sources. But since flashguns exhibit several advantages over heat light sources, namely
 high intensities at short firing times, low heat production and small aperture stops, we developed a multispectral flash acquisition system: We use a multispectral camera with a bandpass filter wheel and sequentially acquire grayscale images, which are then combined into a multispectral image.
 For each filter wheel position, we trigger the flash. The colorimetric analysis of the estimated spectra shows that flash light multispectral imaging performs comparably to a heat light source system, with a mean color error of &#x394;&#x112;<sub>00</sub> = 1.594. We consider several aspects
 specific to flash light sources, namely the spectrum, repeat accuracy, illumination uniformity, calibration of the system, interference stripes and synchronization.</p>
      </abstract>