<!DOCTYPE article PUBLIC '-//NLM//DTD Journal Publishing DTD v2.1 20050630//EN' 'http://uploads.ingentaconnect.com/docs/dtd/ingenta-journalpublishing.dtd'>
<article article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="aggregator">72010350</journal-id>
      <journal-title>Color and Imaging Conference</journal-title>
      <abbrev-journal-title>color imaging conf</abbrev-journal-title>
      <issn pub-type="ppub">2166-9635</issn><issn pub-type="epub"></issn>
      <publisher>
        <publisher-name>Society for Imaging Science and Technology</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.2352/ISSN.2169-2629.2018.26.67</article-id>
      <article-id pub-id-type="sici">2166-9635(20181112)2018:1L.67;1-</article-id>
      <article-id pub-id-type="publisher-id">s12.phd</article-id>
      <article-id pub-id-type="other">/ist/cic/2018/00002018/00000001/art00012</article-id>
      <article-categories>
        <subj-group>
          <subject>Articles</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Using Chromaticity Error Minimisation for Fast Camera Spectral Responsivity Measurement</article-title>
      </title-group>
      <contrib-group>
        <contrib>
          <name>
            <surname>Karge</surname>
            <given-names>Andreas</given-names>
          </name>
        </contrib>
        <contrib>
          <name>
            <surname>Rieger</surname>
            <given-names>Ingmar</given-names>
          </name>
        </contrib>
        <contrib>
          <name>
            <surname>Eberhardt</surname>
            <given-names>Bernhard</given-names>
          </name>
        </contrib>
        <contrib>
          <name>
            <surname>Schilling</surname>
            <given-names>Andreas</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date>
        <day>12</day>
        <month>11</month>
        <year>2018</year>
      </pub-date>
      <volume>2018</volume>
      <issue>1</issue>
      <fpage>67</fpage>
      <lpage>74</lpage>
      <permissions>
        <copyright-year>2018</copyright-year>
      </permissions>
      <abstract>
        <p>Measuring the spectral responsivity of a camera using a monochromator is time-consuming and expensive. This work evaluates afast responsivity measurement method, where diffraction spectrum images are captured and then used for estimating camera responsivity. An error was noticed in
 the previously proposed measurement method that was caused by spectroradiometer measurement errors and vignetting effects from the camera's lens and sensor. Therefore, a correction step using chromaticity error minimisation is presented to adjust the initial responsivity estimate. It requires
 a chart to be captured under a known illumination. The chromaticity error of the improved procedure is approximately one order of magnitude smaller than the original error. This enhanced method was employed to create a dataset of spectral responsivities for machine vision, photographic, and
 movie cameras, which is presented here.</p>
      </abstract>
    </article-meta>
  </front>
</article>